PA01

Single Point Aluminum Load Cell


Features

  • Capacity 3-90kg
  • Anodized Aluminum Construction
  • Single point 400x400 mm platform
  • Three Beam Structure
  • 6 Wire with Sense Circuit
  • Adjustable Overload Protection
  • Fully compatible to Vishay 1010. Vishay 1015 compatible is also avaible to order.
  • IP54 protection, IP67 available

Outline Dimensions

Mounting

M6 8.8 screws with socket head, tightening torque 7NM

Specifications

PARAMETER UNIT VALUE
True-Tec Grade N P R
Rated capacity (E max) kg 3*, 5, 7, 10, 15, 20, 30, 50*, 90*
Sensitivity mV/V 2.00
Sensitivity tolerance ± mV/V 0.20
Zero balance ± mV/V 0.10
Maximum Number of Intervals 2000 2500 3000
Y=Emax/vmin Typical 3600 4500 6000
Z=Emax/(2*DR) Typical 2000 2500 3000
Eccentric loading error ±%/cm 0.0074 0.0074 0.0049
Maximum platform size cm 40x40
Nominal temperature range °C -10 to +40
Service temperature range °C -30 to +70
Limit load % of R.C. 150
Break load % of R.C. 300
Nominal excitation V 10
Max. excitation V 15
Input impedance Ohm 406 ± 15
Output impedance Ohm 350 ± 3
Insulation resistance MOhm > 2000
Compensation circuit type Balanced Bridge
Cable length m 1.0
Cable type 6x26 AWG, Black PVC Jacket
Color code +exc -green, +sen-blue, +sig-red, -exc-black, -sen-brown, -sig- white
Construction Aluminum
Protection class to IEC529 IP 54, IP67 Optional

Note: 3kg, 50kg and 90kg available in N grade only

Applications

Model PA01 is a single point load cell designed for industrial applications where space is limited. Typical applications include bench scales and process weighing.

A special humidity resistant protective coating assures long-term stability over the entire compensated temperature range.