PA04
Single Point Aluminum Load Cell
FEATURES
- Capacity 150g-3000g
- Up to 100,000 divisions short term precision at room temperature
- Maximum platform size 200x200 mm at 3000 divisions
- IP 66 protection
- Load cell error better than 0.0048% at rated output available
OUTLINE DIMENSIONS
MOUNTING
M3 8.8 class socket head screw, tightening torque 1.4Nm
SPECIFICATION
PARAMETER | UNIT | VALUE | |||
---|---|---|---|---|---|
Rated Capacity (E max) | g | 150*, 300*, 600, 1200, 1500, 3000 | |||
True-Tec Grade | R | S | U | V | |
Sensitivity | mV/V | 0.90 | |||
Sensitivity tolerance | ± mV/V | 0.10 | |||
Zero balance | ± mV/V | 0.10 | |||
Y=Emax/vmin | Typical | 4000 | 5000 | 6000 | 8000 |
Z=Emax/(2*DR) | Typical | 3000 | 4000 | 5000 | 6000 |
Creep (From stable to 2min.) | ±% | 0.0085 | 0.0050 | 0.0033 | 0.0028 |
Temperature effect on output | ±%/°C | 0.0014 | 0.0012 | ||
Linearity | ±% | 0.0120 | 0.0100 | 0.0060 | 0.0045 |
Repeatability | ±% | 0.0090 | 0.0050 | 0.0040 | 0.0030 |
Hysteresis | ±% | 0.0080 | 0.0045 | 0.0032 | 0.0025 |
Eccentric Loading error | ±%/cm | 0.0042 | 0.0042 | 0.0036 | 0.0024 |
Norminal Temperature range | °C | +10 to +40 | |||
Service Temperature range | °C | -30 to +70 | |||
Limit Load | % of R.C. | 200 | |||
Break Load | % of R.C. | 300 | |||
Norminal Working Humidity | % RH | 20 to 65 | |||
Norminal Excitation | V | 5 | |||
Max Excitation | V | 15 | |||
Imput Impedance | Ohm | 406 ± 15 | |||
Output Impedance | Ohm | 350 ± 3 | |||
Insulation | MOhm | > 2000 | |||
Cable Length | meter | 0.35 | |||
Cable Type | 4x28AWG Aluminum-Mylar foil shielded Black PVC jacket cable | ||||
Color code | +exc-green, +sig-red, -exc-black,-sig-white | ||||
Construction | Non-Anodized Aluminum Alloy | ||||
Compensation circuit type | Balanced Bridge | ||||
Protection class to IEC529 | IP 66 |
Note: Optional width of 8mm available
APPLICATIONS
Model PA04 is a very low capacity, very high precision single point load cell designed for direct mounting in low capacity scales and precision balances.
The PA04 offers up to 100,000 divisions short term precision at room temperature. This load cell is ideal for applications including jewelry scales, analytical balances, medical equipment, medical and pharmaceutical research and low level force measurement.
A threaded hole in the loading end of the load cell is provided for overload protection.