FEATURES

  • Capacity 3-90kg

  • Anodized Aluminum Construction

  • Single point 400x400 mm platform

  • Three Beam Structure

  • 6 Wire with Sense Circuit

  • Adjustable Overload Protection

  • IP54 protection, IP67 available


OUTLINE DIMENSIONS:

MOUNTING

M6 8.8 screws with socket head, tightening torque 7NM


APPLICATIONS:

Model PA01 is a single point load cell designed for industrial applications where space is limited. Typical applications include bench scales and process weighing.

A special humidity resistant protective coating assures long-term stability over the entire compensated temperature range.

 


SPECIFICATION:

PARAMETER

UNIT

VALUE

True-Tec Grade

 

N

P

R

Rated capacity (Emax)

kg

3*,5,7,10,15,20,30,50*,90*

Sensitivity

mV/V

2.00

Sensitivity tolerance

± mV/V

0.20

Zero balance

± mV/V

0.10

Maximum Number of Intervals

 

2000

2500

3000

Y=Emax/vmin

Typical

3600

4500

6000

Z=Emax/(2*DR)

Typical

2000

2500

3000

Eccentric loading error

±%/cm

0.0074

0.0074

0.0049

Maximum platform size

cm

40x40

Nominal temperature range

°C

-10 to +40

Service temperature range

°C

-30 to +70

Limit load

% of R.C.

150

Break load

% of R.C.

300

Nominal excitation

V

10

Max. excitation

V

15

Input impedance

Ohm

406 ± 15

Output impedance

Ohm

350 ± 3

Insulation resistance

MOhm

>2000

Compensation circuit type

 

Balanced Bridge

Cable length

Meter

1.0

Cable type

 

6x26 AWG, Black PVC Jacket

Color code

 

+exc -green, +sen-blue, +sig-red, -exc-black, -sen-brown, -sig- white

Construction

 

Aluminum

Protection class to IEC529

 

IP 54, IP67 Optional

Note: 3kg, 50kg and 90kg available in N grade only