PA02

Single Point Aluminum Load Cell


FEATURES

  • Capacity 300g-5kg
  • Up to 60,000 divisions short term precision at room temperature
  • Single point 200x200 mm platform
  • IP66 protection
  • Interchangeable with C2X1, PW4M, 1006

OUTLINE DIMENSIONS

MOUNTING

M3 8.8 class socket head screw, tightening torque 1.4Nm

SPECIFICATION

PARAMETER UNIT VALUE
Rated Capacity (E max) 300G, 600G 1kg, 2kg, 3kg, 5kg
Sensitivity mV/V 0.90 2.00
Sensitivity tolerance ± mV/V 0.10 0.20
Zero balance ± mV/V 0.10
True-Tec Grade R S U
Creep (From stable to 2min.) ±% 0.0085 0.0050 0.0033
Creep over 30min. ±% 0.0150 0.0125 0.0100
Temperature effect on Zero ±%/°C 0.0040 0.0033 0.0025
Temperature effect on output ±%/°C 0.0014 0.0012 0.0010
Linearity ±% 0.0120 0.0100 0.0060
Repeatability ±% 0.0090 0.0050 0.0040
Hysteresis ±% 0.0080 0.0045 0.0036
Eccentric Loading error ±%/cm 0.0042
Norminal Temperature range °C 0 to +40
Service Temperature range °C -30 to +70
Limit Load % of R.C. 200
Break Load % of R.C. 300
Norminal Excitation V 5
Max Excitation V 15
Imput Impedance Ohm 406 ± 15
Output Impedance Ohm 350 ± 3
Insulation MOhm > 2000
Cable Length meter 0.35
Cable Type 4x28AWG Aluminum-Mylar foil shielded Black PVC jacket cable
Color code +exc-green, +sig-red, -exc-black,-sig-white
Construction Non-Anodized Aluminum Alloy
Compensation circuit type Balanced Bridge
Protection class to IEC529 IP 66

APPLICATIONS

Model PA02F is a very low capacity, high precision single point load cell designed for direct mounting in low capacity scales and precision balances.

The PA02F offers up to 60,000 divisions’ short term precision at room temperature. This load cell is suitable for applications including postal scales, counting scales, precision balances, and is also suitable for a wide variety of force measurement applications, such as industry process control where the acting center of force application is within 100mm from the load cell vertical axis.