PA06R
Single Point Aluminum Load Cell
FEATURES
- Capacity 3-200kg
- Aluminum Construction
- Specially designed for dynamic weighing
- Single point 350x350 mm platform
- IP66 protection
- OIML R60 approved up to C6 grade, NTEP approved to Class IIIS 6000d.
- HBM PW6D compatible
OUTLINE DIMENSIONS
MOUNTING
M6 8.8 class socket head screw, tightening torque 7NM
SPECIFICATION
PARAMETER | UNIT | VALUE | ||||
---|---|---|---|---|---|---|
True-Tec Grade | R | T | V | |||
Rated Capacity (E max) | kg | 3*, 5, 7, 10, 15, 20, 30, 35, 50, 75, 100, 150, 200 | ||||
Sensitivity | mV/V | 2.00 | ||||
Sensitivity tolerance | ± mV/V | 0.20 | ||||
Zero balance | ± mV/V | 0.10 | ||||
Maximum Number of Intervals | 3000 | 4000 | 6000 | |||
Y=Emax/vmin | Typical | 10000 | 10000 | 10000 | ||
Z=Emax/(2*DR) | Typical | 3000 | 4000 | 6000 | ||
Eccentric Loading error | ±%/cm | 0.0049 | 0.0036 | 0.0024 | ||
Maximum platform size | cm | 35x35 | ||||
Nominal temperature range | °C | -10 to +40 | ||||
Service temperature range | °C | -30 to +70 | ||||
Limit load | % of R.C. | 150 | ||||
Break load | % of R.C. | 300 | ||||
Nominal excitation | V | 10 | ||||
Max. excitation | V | 15 | ||||
Input impedance | Ohm | 406 ± 15 | ||||
Output impedance | Ohm | 350 ± 3 | ||||
Insulation resistance | MOhm | > 2000 | ||||
Compensation circuit type | Balanced Bridge | |||||
Cable length | m | 0.75 | ||||
Cable type | 4x28 AWG, Aluminum Mylar Foil Shielded, Black PVC Jacket | |||||
Color code | +exc-green, +sig-red, -exc-black, -sig- white | |||||
Construction | Anodized Aluminum Alloy** | |||||
Protection class to IEC529 | IP 66 |
Note:*3kg capacity is approved to C3 only ** 3kg and 5kg load cell are not anodized.
Applications
Model PA06R is a low profile single point load cell designed for dynamic weighing applications, and where cable exit from backside is required.
Its small physical size, combined with high accuracy and aluminum construction, makes this low cost load cell ideally suited for retail, bench and counting scales where savings in parts and labor due to simpler scales construction can be made.
Available in a range of capacities, 3kg to OIML R60 C3 (3000e), and 5kg to 200kg approved to C6 (6000e). Environment protection to IP66 is provided as standard.